<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-26 09-00-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 67 dBuV ISKELMA
Pilot RDS Phase Difference
6.5 kHz 2.9 kHz -86 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 18979 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,6 dBr 5,42 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2024/07/26 8.59.16 Total samples: 18979 Equivalent time: 0:15:48 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 6,5 dBr MIN: 3,6 dBr AVE: 5,42 dBr % above 12,2 dBr: 0,0 Last value: 3,7 dBr (2024/07/26 8.59.15) 08.46 08.48 08.50 08.52 08.54 08.56 08.58 0 2 4 6 Pm [dBr]